,
,
, 

,
,
, 
The XMPi pressure transmitter is an advanced device for heavy industry and the oil & gas, food and pharmaceutical sectors. Measuring range from -1 to 600 bar, HART digital communication, versions for hazardous areas and SIL2.
-1 ... 600 bar
-40 ... 125 °C
0.1 %
The XMPi pressure transmitter is an advanced measuring device designed for heavy industry, including the oil & gas sector, while also meeting the equally high requirements of the food and pharmaceutical industries. It measures vacuum as well as gauge and absolute pressure from -1 to 600 bar, making it suitable for almost any process application. It is available with various process connections – threaded and flanged, with an internal or flush diaphragm – and in the version with a cooling element it can handle media up to 300°C. HART digital communication is standard, and the housing can be selected as a dual-chamber aluminium version or a stainless steel field housing. The design allows operation both in safe areas and in hazardous areas, as well as in installations requiring safety integrity level SIL2.
The robust design of the XMPi transmitter is based on proven measurement technology in which the measuring diaphragm transfers pressure to the sensor via a fill fluid, ensuring high long-term stability and overload resistance. The housing, available as a dual-chamber aluminium version or a stainless steel field version, allows the device to be matched to the conditions in the installation, including those with increased humidity or exposure to the weather.
HART digital communication allows remote configuration of operating parameters, calibration and diagnostics without removing the device from the installation, which significantly reduces service downtime. Versions with an LCD display allow local reading of the measured value and diagnostic parameters directly on site.
HART communication
Range up to 600 bar
Special diaphragm materials (Hastelloy, tantalum)
ATEX Ex ia / Ex d version
SIL2 certificate
Cooling element up to 300°C

A standard accuracy class of 0.1% ensures precise and stable pressure measurement even in demanding heavy-industry process conditions. High repeatability allows precise process control and meets the strict quality requirements of the oil and gas, chemical and power industries, where even a small measurement deviation can affect the safety and efficiency of the installation.
Range turndown of 1:10 allows the transmitter to be adapted to many different applications without changing the device. This means fewer device variants need to be stocked, reducing inventory costs, while providing configuration flexibility when process parameters change and making it easier to standardise the plant’s measuring equipment.


Available ATEX versions (Ex ia, Ex d) and SIL2 certification allow the transmitter to be used in installations with increased safety requirements. The certified explosion-proof design allows installation in areas with a risk of gas and dust explosions, and safety integrity level SIL2 confirms the high reliability of safety systems in critical process applications.
| Measuring range | -1…600 bar |
| Output signal | HART, 4…20 mA (2-wire) |
| Accuracy class | 0.1% |
| Process temperature | standard -40…125°C, with cooling element up to 300°C |
| Housings | powder-coated aluminium casting or stainless steel 316L |
| Seals | FKM, EPDM or PTFE |
| Threaded connections | standard G½” DIN 3852, others as per data sheet |
| Electrical connection | terminal block |
| EX certificate | ATEX (Ex ia, Ex d) |
| Other certificates / approvals | CE, PED, SIL2 |
| Communication | HART® |
| Diaphragm materials | Hastelloy, tantalum |
| Housing | dual-chamber aluminium or stainless steel field housing |
| Cooling element | for media up to 300°C |
Given the challenges facing the oil and gas industry, process optimisation and cost minimisation are becoming key to staying competitive. At KERTO we understand these needs and offer our customers measurement solutions and field support that help maximise production efficiency. We meet these needs with robust, maintenance-free measurement technology. Our extensive experience in supplying instruments and solutions to the oil and gas industry at every stage of production – from extraction, through storage and the transmission network, to processing – has made us a recommended supplier of measurement solutions. We offer comprehensive measurement for well developments, LNG regasification, gas compressor station construction and gas and crude oil storage. Typical applications of our products include:
Separators are process units very widely used to clean and separate crude oil and natural gas. Their designs can vary greatly. The simplest may consist of a pressure vessel fitted only with a simple inlet device and a vortex breaker, while more complex ones also have demisters or various combinations of them, and baffles. By process purpose, separators are divided into two-phase, three-phase, centrifugal, gravity mesh and combined separators. All of them, regardless of design or vertical or horizontal orientation, require instrumentation to indicate pressure, level, temperature and flow. You will find all the instruments dedicated to this application in our range.
The degasser is used to separate residual gas and gasoline from produced water. In the produced water routed from the primary separators and the gas drying column to the degasser, gas and gasoline are released under elevated temperature. The gas obtained in this way is routed to the combustion system, the gasoline to the gasoline tank and the cleaned produced water to the storage tank. Every degasser, produced water storage tank and gasoline tank is fitted with nozzles for level gauges, pressure gauges and thermometers.
Methanol is used mainly for dehydration and de-icing in the oil and gas industry. Methanol is injected both continuously and intermittently. It prevents hydrate formation, mainly on drilling platforms, and lowers the freezing point of water solutions during the transport of crude oil and natural gas. Every methanol injection unit must be constantly monitored and topped up, and for this purpose we use magnetic level gauges.
LNG is produced from natural gas by liquefaction. LNG regasification means returning the gas from its liquefied form to the gaseous state by heating the liquefied product. The basic equipment in an LNG regasification plant are vaporisers of various capacities, designs and heating methods. Before it reaches the customer’s gas installation, the regasified gas is odorised, giving it a characteristic smell, and the use of detection systems makes the use of natural gas very convenient and safe. At KERTO you will find cryogenic and odorisation equipment.
Given the difficulties faced by the petrochemical industry, process optimisation and cost-efficient operation are crucial. At KERTO we fully understand these challenges and help our customers increase efficiency by offering measurement solutions that improve application performance. We have extensive experience in supplying measurement solutions for the oil sector at every stage of the production chain. We supply complete solutions, from level measurement of multiphase media to instruments for measuring steam and gas pressure in refineries. Typical applications of our products include:
Crude oil desalting removes contaminants such as salts, water, sediments and metals, which can corrode refinery equipment and poison catalysts. The process involves adding demulsifiers and washing with fresh water to break the emulsion and dilute the contaminants. Desalting takes place at around 150°C and is controlled by interface measurement systems. The wash water is discharged to the wastewater treatment plant. At KERTO we offer local level measurement of multiphase media.
After desalting, the crude oil is heated to 375°C and fed into the distillation column. In the column, the oil vapours cool, and different fractions such as gasoline and kerosene condense and are separated. The process is supported by heat exchange with the crude oil, and the lightest fractions collect at the top of the column. The heavier oil, with a boiling point above 375°C, goes to the vacuum column, where the vacuum lowers the boiling points, preventing coke formation and blockages. We ensure reliable measurement even in difficult high-temperature applications.
Fluid catalytic cracking (FCC) is a process in which long-chain hydrocarbons from lighter gas oil fractions are converted mainly into gasoline. Hot gas oil is mixed with catalyst and steam, and the reaction products are separated in a distillation column and separators. FCC units run continuously for several years, so it is essential that monitoring systems are reliable and efficient. At KERTO we provide safe measurement regardless of process conditions.
Hydrocracking is a catalytic cracking process used for heavy vacuum gas oil from vacuum distillation. It involves mixing the oil with hydrogen and breaking long hydrocarbon chains into shorter ones using a catalyst. The products and efficiency of the process depend on temperature and catalyst. The main products of hydrocracking are jet fuel and diesel, so it is used where demand for them is high. Where demand for gasoline is higher, fluid catalytic cracking (FCC) is used more often. Each of these processes requires reliable measurement, which you will find in the KERTO range.
New sustainable power generation processes, waste heat recovery and denser power grids are posing new challenges for the industry. In all areas of power generation, safety and security of supply are of key importance. KERTO offers suitable level, point level and pressure measurement for various applications. Typical applications of our products include:
Industrial boilers supply steam and hot water to production plants, covering around 70% of the energy demand in the process industry. The key factors are the requirements for steam, hot water, fuel type and emission standards. Boilers in cogeneration also process production waste. Combustion systems allow various fuel mixtures to be burned. Fuel gas requires pressure regulation, drying and measurement of flow and calorific value before use. At KERTO we offer magnetic and glass level gauges for measuring the steam drum level. Water level control is of great importance for safe operation.
Steam turbines in combined cycle plants are specially developed as multi-pressure condensing types, using cooling water from a cooling tower or an air cooler, directly coupled to the generator and optimised for reheat. All these cooling water, water treatment, deaeration and storage systems have many tanks that require level, pressure and temperature monitoring and control. This can be achieved with RF-90 guided wave radar transmitters and AQUARIUS series magnetic level gauges with level switches, which can operate in redundant configurations.
The steam drum, often called the “heart” of a natural-circulation steam boiler, is a pressure vessel located in the upper part of the boiler, outside the flue gas flow zone. Its main function is to separate steam from water. The steam drum is a place of highly variable thermodynamic conditions, with high temperature and pressure. Maintaining the correct water level in the drum is a critical factor in ensuring its proper operation, which is why at KERTO we offer specialised bicolour level gauges for the extreme conditions inside the steam drum.
The steam in the condenser is used to supply energy to the district heating network. The outlet temperature of the heating water is controlled according to weather conditions. In this system, the condensate level is monitored by a sensor that measures the fill level. AQUARIUS series magnetic level gauges and LIQUIDUS series glass level gauges are ideal for reliable measurement.
KERTO measuring instruments are also used on ships sailing the world’s oceans. They are used for measurements in cargo containers, water and expansion tanks, and in heel and draught monitoring systems. Our solutions are installed on various types of vessels – from small inland vessels to huge ocean-going ships.
Ocean-going ships consume large amounts of fuel for propulsion, power generation and other on-board processes. Fuel costs usually account for a significant share of the operating costs of merchant ships. To make economical use of the loading capacity and to control the pumps efficiently, the fill level is measured continuously and the point level is monitored.
Ships take on ballast water to maintain proper stability during voyages, especially when they carry little cargo or are empty. This water goes into special ballast tanks. To monitor pump operation, pressure and level measurements are carried out regularly, allowing any faults to be detected quickly.
Hydraulic oil, used to transmit power, circulates in a closed circuit. It is consumed at lubrication points and at points where leaks occur in the power plant. To ensure the power plant runs smoothly, the hydraulic oil level in the tank must be monitored continuously.
The chemical industry uses proven technologies that guarantee the highest quality, performance and cost-effectiveness. At KERTO we supply reliable instruments for level measurement, point level detection and pressure and temperature monitoring – all characterised by reliability, safety and ease of use.
Crude oil is heated in a furnace to around 375°C and then enters the bottom of the atmospheric distillation column, where it is at a pressure slightly above atmospheric. As the oil vapours rise through the column and gradually cool, the individual fractions with different boiling points condense and are drawn off from the sides of the column. These liquid fractions, called side streams, include products such as heavy naphtha, kerosene and light diesel oil. We ensure reliable measurement even in difficult high-temperature applications.
Ammonia is widely used as an industrial gas in many sectors. It is used, among other things, for steel hardening, as a refrigerant and for the production of plastics and synthetic fibres. In the ammonia separator, the reaction gas mixture is cooled to below the boiling point of ammonia (-33 °C), causing the ammonia to condense. In the separators we use AQUARIUS magnetic level gauges with an RF-90 guided wave radar and a vibrating level switch in a combined two-column version on a single pair of process nozzles.
Caprolactam is mainly used as a raw material for producing polyamide-6 fibres. Because of the complexity of its production process, precise control is essential to ensure proper product quality and maximum production efficiency. KERTO supplies a wide range of measuring instruments that meet the highest standards of quality and performance.
Urea is used as an additive for AdBlue and as a basic substance for the chemical industry in the production of urea resins for adhesives, impregnating agents and insulation materials. Today urea is mainly produced industrially from ammonia and carbon dioxide. In a high-pressure reactor they react to form ammonium carbamate, which under suitable conditions slowly decomposes as an intermediate into urea and water. Liquid urea is stored in corrosion-resistant tanks. At KERTO you will find measuring instruments resistant to corrosion and liquid fertilisers.
Caustic soda is produced by membrane electrolysis. It is used in almost every branch of industry. It is an extremely corrosive substance and very dangerous to humans, so its storage requires suitable materials. AQUARIUS magnetic level gauges made of plastic, or of stainless steel with ECTFE-coated wetted parts, will fully ensure correct level measurement.
Instrument enclosures and sunshades are key protective elements whose main task is to protect measuring instruments against corrosion and mechanical damage. They effectively isolate the equipment from the harmful effects of harsh weather, such as extremely low temperatures, excessive moisture or direct sunlight. The covers offered by KERTO are made of hot-pressed, single-layer glass-fibre-reinforced polyester resin (GRP). This advanced material makes the housing exceptionally light while maintaining maximum resistance to external factors, which is essential in demanding industrial environments.


Valve manifolds are advanced multi-way valve assemblies that combine shut-off, venting and pressure equalisation in a single compact block. They are indispensable when installing pressure gauges and differential pressure transmitters, reducing the number of pipe connections required and thus minimising the risk of leaks. KERTO offers 2-, 3- and 5-way manifolds that enable safe servicing of instruments, zero calibration and controlled pressure release. Machining from a single block of high-grade steel ensures extreme durability and reliability.
Protective accessories are an essential addition to measuring systems, protecting the delicate mechanisms of pressure gauges against damaging process phenomena. Loop and siphon tubes effectively lower the temperature of the medium (e.g. hot steam) before it reaches the instrument, preventing thermal damage. Pulsation dampers smooth out sudden pressure spikes and installation vibration, stabilising the reading, while pressure limiters automatically shut off the supply when a set safe value is exceeded. The complete range of equipment supplied by KERTO guarantees the reliability of every measuring point.

Use the form below to receive technical documentation.
Gauge pressure: Measured relative to the current atmospheric pressure. The transmitter reads “0” when the process pressure equals ambient pressure. This is the most common type of measurement.
Absolute pressure: Measured relative to a perfect vacuum (0 bar absolute). The atmospheric pressure (approx. 1 bar) is already included. It is used in applications where weather and atmospheric pressure fluctuations could affect process precision (e.g. vacuum applications, laboratories).
Differential pressure: The device has two connections and measures the pressure difference between two points. It is used to measure the level in sealed pressure vessels, monitor filter clogging or measure flow (together with orifice plates/venturi tubes).
Pressure transmitters are advanced measuring devices that convert a physical pressure value into a proportional standard electrical signal (e.g. 4…20 mA analogue, voltage or digital HART). They are used in all industries: from heavy industry, petrochemicals and power generation (advanced XMPi and XMD models), through pneumatics, machine hydraulics and HVAC systems (economical 26.600, 18.600 and 17.600 models), to precision medical technology, refrigeration systems and the food and pharmaceutical industries, where hygienic-standard devices are used (e.g. DMP 331P).
Depending on the wetted materials and connection type, transmitters can measure almost any medium, including: clean liquids (water, juices), gases (air, nitrogen, industrial gases), steam, viscous sludges, pastes, adhesives, crystallising liquids and liquids contaminated with solids (a flush diaphragm is recommended here), as well as highly aggressive chemicals (acids, alkalis – requiring a ceramic diaphragm, PTFE coatings or Hastelloy/tantalum alloys).
When specifying an order or designing an installation, the following criteria should be considered:
Measuring range: Minimum and maximum operating pressure (e.g. 0…10 bar).
Permissible overload (overpressure): Resistance of the sensor to momentary pressure surges exceeding the measuring range without damaging the diaphragm.
Accuracy / basic error: Expressed in % of span (e.g. 0.1% for advanced process devices, 0.5% or 1% for economical applications).
Operating temperature: Permissible process medium temperature and ambient temperature of the electronics.
Material of wetted parts: Must be fully chemically compatible with the measured medium.
Output signal: Communication standard with the PLC (e.g. 4…20 mA).
OEM (Original Equipment Manufacturer) transmitters: Designed for mass production of machines, vehicles or HVAC systems. They are compact, fully cost-optimised and have fixed factory-set parameters (no on-site calibration). They use quick-connect (plug-in) electrical connectors.
Industrial (process) transmitters: Advanced devices for heavy industry (e.g. refineries). They have robust, heavy-duty field housings (aluminium or stainless steel), LCD displays, allow on-site reconfiguration (e.g. via HART) and hold numerous certificates (ATEX for hazardous areas, SIL for safety circuits).
Current signal (usually 4…20 mA, two-wire): The industrial standard. It is extremely resistant to electromagnetic interference over long cable runs. 4 mA corresponds to zero, which also makes it possible to detect a broken circuit (the signal drops to 0 mA if the cable fails).
Voltage signal (e.g. 0…10 V, 1…5 V, three-wire): Common in OEM devices, machines and HVAC systems with short transmission distances.
Digital communication (e.g. HART, IO-Link, Profibus): A bidirectional digital protocol, often superimposed on the current loop (HART), enabling self-diagnostics, digital trimming and reading parameters from the device without going to the installation.
Extreme temperature is the biggest threat to transmitters. High temperatures (e.g. above 125°C) can overheat the electronics and melt the seals. In addition, temperature fluctuations change the density and volume of the fill fluid inside the connection. This causes small shifts in the reading of the piezoresistive element, which shows up in the system as a measurement error and so-called “temperature zero drift”.
If the process medium prevents a standard transmitter from being connected, an external diaphragm seal is required. The main benefits are:
Thermal protection: A diaphragm seal mounted on a capillary drastically lowers the temperature reaching the electronics, allowing media at around 300°C – 400°C to be measured.
Clogging prevention: The large flat flush diaphragm prevents crystallisation or deposits from thick sludges.
Corrosion protection: Protective coatings (e.g. PTFE, gold) can be applied only to the external diaphragm, protecting the expensive measuring system.
Yes. For oil & gas and chemical plants, advanced transmitters such as BAROS XMPi and BAROS XMD are offered with full European ATEX certification. They can be ordered as intrinsically safe (Ex ia) or in a flameproof enclosure (Ex d). They also meet the stringent requirements of safety integrity level SIL2, so they can form an integral part of the protection of critical industrial systems.
For thick, strongly crystallising or solids-laden liquids in demanding processes, we recommend transmitters combined with external diaphragm seals (e.g. the XMD series with capillaries) or transmitters with a flush sensor diaphragm. Alternatively, for acids or abrasive sludges, versions based on fully sintered ceramics, such as the DMK 331 and 26.600, are ideal.
See all frequently asked questions about Kerto Automation products.
If you can't find the product or need help choosing the right measuring solution, write to us.
We want your experience on our website to be as comfortable as possible. Therefore, you can easily change the language by clicking on the appropriate flag at the top of the page. Thanks to this, we will adapt the content especially for you. Enjoy browsing!

Use the form below to receive an offer tailored to your specific requirements.

Contact our sales representative!
We will do our best to find the perfect product to meet your requirements.